How to Specify LED Strip: Six Numbers That Decide It

A specification checklist for LED strip: flux per metre, CRI and R9, SDCM, voltage and run length, IP rating and L70 at case temperature. With a template.

HFY Applications Engineering · Published September 22, 2026 · 4 min read

Short answer

A usable LED strip specification states flux per metre at a given CRI and CCT, the binning tolerance in SDCM steps, voltage and maximum run length, IP rating with installation conditions, and L70 life at a stated case temperature. Six numbers, all measurable, all verifiable against a test report. Anything else on the datasheet is marketing copy.

Key points

  • Flux quoted without CCT and CRI is not a specification — the same strip varies 40% across those two variables.
  • CRI hides red rendering; R9 must be specified separately or the result will be a strip that makes red look brown.
  • L70 without a case temperature is meaningless; a sealed profile runs 20 °C hotter than the test condition.
  • IP67 does not mean chemical resistance, and it does not mean the driver can sit in the wet zone.

The six numbers

#NumberExampleWhy it matters
1Flux per metre at stated CRI/CCT1,150 lm/m at CRI 90, 3000 KSets illuminance; varies 40% across CRI and CCT
2CRI and R9CRI 90, R9 ≥ 50Determines whether colours look correct
3SDCM≤ 3 within a projectDetermines whether adjacent runs match
4Voltage and max run length24 V, 10 m from one feedDetermines the electrical design
5IP rating with installation conditionsIP67, jets and temporary immersionDetermines whether it survives
6L70 and case temperatureL70 50,000 h at 45 °CDetermines whether it lasts

If a datasheet is missing any of these, the quotation is not comparable to another supplier’s quotation, and the difference will appear on site.

Number 1: flux, and why the datasheet misleads

A 2835 strip at 120 LEDs/m and 14.4 W/m can be quoted at 2,100 lm/m at CRI 80, 4000 K — or 1,450 lm/m at CRI 95, 2700 K. Both are honest figures for the same physical product family. Specifying “2,000 lm/m” without the conditions allows a supplier to meet the number with the cheapest bin.

Write the requirement as: 1,400 lm/m minimum at CRI ≥ 90, 3000 K ±100 K, measured to LM-79 on a 0.5 m sample.

Number 2: CRI is not enough

CRI is an average of eight pastel test colours and deliberately excludes saturated red. A strip can score CRI 90 while rendering red at R9 = 12, which is why red garments look brown and timber looks grey under some nominally high-CRI strip.

For retail, hospitality and residential interiors, specify CRI 90 + R9 ≥ 50 as a pair. For fashion and food, R9 ≥ 60.

Number 3: SDCM, the project-level number

SDCM is a per-reel property, but the specification that matters is project-level: how many reels will be visible together, and will they come from one production lot?

  • Single room, one reel: SDCM 5 is fine.
  • Continuous cove, multiple reels: SDCM ≤ 3, one lot.
  • Multi-phase project over months: SDCM ≤ 2 with a reserved bin.

The mechanics of binning are covered in colour consistency for LED strip.

Number 4: voltage and run length, stated together

“24 V” alone says nothing useful. The specification must say maximum run length per feed at the specified wattage and copper weight. A 24 V strip at 15 W/m runs 6 m from one feed; the same strip at 8 W/m runs 11 m. See voltage drop for the calculation.

Number 5: IP rating plus conditions

IP67 is a test result for jets and temporary immersion, not a warranty against a pool environment or a chemical wash-down. Write the installation conditions into the specification:

IP67 silicone extrusion, mounted in a drained aluminium channel, driver in a separate IP65 enclosure outside the wet zone, cleaning with pH-neutral products only.

That sentence prevents most of the warranty disputes we see.

Number 6: life at a temperature

L70 at 25 °C is a laboratory number. In a sealed 15 mm profile the strip runs 55–65 °C and reaches L70 in roughly half the rated hours. Specify the case temperature the installation will actually produce, and ask for L80 if the space is difficult to service.

A specification template

COB LED strip, 480 chips/m, 24 V, 12 W/m, 1,100 lm/m minimum at CRI 90 with R9 ≥ 50, 3000 K ±100 K, SDCM ≤ 3 across the whole order from one production lot, 25 mm cut length, IP20 in a ventilated profile, L80 50,000 h at 45 °C case, 5 m reels with JST SM connectors, bin code on the reel label.

Every clause in that sentence is measurable, and every clause can be verified against a shipment. For the stocked configurations that meet it, see COB LED strip; for volume projects where cost per lumen dominates, the trade-offs are in COB vs SMD.

This article describes general manufacturing practice for machined and fabricated components. It is not a substitute for a drawing-specific engineering review — tolerances, material selection and process capability depend on the individual part.

Questions

Frequently asked

What CRI should I specify for a commercial project?

CRI 90 with R9 ≥ 50 for offices, retail and hospitality interiors. CRI 80 is acceptable only in back-of-house, car parks and industrial spaces where colour appearance does not matter. Below CRI 80, the light makes skin tones grey and timber flat, and no amount of lumen output fixes that.

Is higher lumens per metre always better?

No. Beyond about 1,600 lm/m in a standard aluminium profile, the strip is limited by heat, not by output: the profile cannot dissipate more than roughly 15 W/m without forced ventilation. A 2,500 lm/m strip in a 15 mm profile runs at 70 °C and reaches L70 in under 20,000 hours.

How do I specify a strip for a 15-year installation?

Specify L80 at the actual case temperature rather than L70 at the test temperature, and add a 2% spare allocation from the same bin. Then check that the driver is accessible for replacement, because in a 15-year installation the driver fails first — usually between year five and year eight.